Herunterladen Inhalt Inhalt Diese Seite drucken

Water Filtering - Jacuzzi lodge Montageanweisung

Vorschau ausblenden Andere Handbücher für lodge:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
- If it is necessary to perform an anti-freeze cycle while a function
activated by the user is in progress, the cycle will be activated 15
minutes after the end of the function.
- If this protection is active, the spotlight may still be turned on.

Water filtering

The water needs to be filtered to keep it clean, clear and inviting. The
pump runs the water through a cartridge filter in the skimmer (see
the chapter on "Maintenance of cartridge filter"). This operation
takes place based on a cycle during the day (filtering cycle) which
repeats every 24 hours.
Some models are also equipped with a special type of fast filter-
ing ("boost"), which differs from the normal cycle due to its brief,
intense duration.
NOTE: in some models, the pump has two speeds: a low
speed used for water circulation and filtration, and a higher
speed to activate the hydromassage jets (in the remaining
models, there is a pump dedicated to this function, the filter-
ing pump).
Setting the filtering cycles
To set the filtering cycle:
Press the "Light"
key and hold it down for about 5 sec-
onds. The display will show the message dx, where "x" indicates
the duration in hours.
Use the key "Up/Down"
from a minimum of 0 to a maximum of 12 hours.
NOTE: hold the key down until you reach the desired value. If the
display is equipped with two separate keys, press the key "Up" to
increase the value or the key "Down" to decrease it.
Pressing the "Light"
ue and then continues with the programming of the start delay,
with respect to the "0" time, of the cycle (parameter sy, where
"y" indicates the number of hours).
ATTENTION: the time "0" is the moment at which the hot tub is
powered on using the main switch, or the moment at which the
parameters are memorized. for example, you set as the cycle start
delay to "4", it means that filtering will start 4 hours after you turn
on the hot tub, or after memorization of said parameters.
It is also possible to reduce the value of parameter "s" to ). In this
case the filtering cycle will start immediately.
Set the start delay (from a minimum of 9 to a maximum of 23) us-
ing the key "Up/Down"
to save the entered value and exit from the programming mode.
When this function is active, the LED of the respective symbol
will turn on. If the LED is blinking, it means that the cycle has been
suspended, see the relative chapter for more information.
NOTES
The factory settings are the following:
- cycle duration: 2 hours.
- start delay compared to time "0": 40 minutes.
to enter the desired duration,
key again confirms the selected val-
and confirm using the "Light"
If no programming is performed, every 24 hours a 2 hour filtering
cycle is performed in any case, and will start 40 minutes after the
hot tub is turned on.
If there is a power outage, the data in the memory is saved, but
the time "0" will become the moment at which the electricity comes
back on. Therefore, it may be necessary to turn the main switch up
the line from the hot tub off and back on to re-align the cycle start
delay with the memorized parameters.
It is possible to vary the filtering cycle setting parameters at
any time by following the procedure provided at the beginning
of this chapter. By modifying these parameters, time "0" is
"shifted" to the time in which the new values are saved.
Suspending the filtering cycles
In versions with a 2-speed pump, the filtering cycle is stopped
when the hydromassage switches on . But it will restart again
from the point in which it stopped 40 minutes after the function
is switched off. This means that if at the moment of interruption
1 hour remained until the end of the cycle, when it restarts, it will
continue for this period of time and will then stop.
The filtering cycle may be suspended by the anti-freeze pro-
tection ("Smart Winter") or due to overheated water. Refer to the
respective chapters.
If the system is in standby mode (see related chapter), the fil-
tering pump stops and is restarted when the system is no longer
in standby mode.
Overheating during filtering cycles
During the filtering cycle, if the water temperature exceeds the
set point by more than 1 °C (2 °F) (see the chapter "Setting the water
heating temperature") and it does not decrease at least 1 °C (2 °F) in
the following 3 hours, the cycle will be suspended until the tempera-
ture does not decrease by at least 1 °C (2 °F) below the set point value.
Even if the water temperature is high (due to excessive sun-
light, for example), filtering is ensured for at least 3 hours.
Clearray™ (optional).
The Clearray™ helps oxidize the organic substances that infil-
trate the water, and therefore reduces the need for chemical prod-
ucts for water treatment.
Clearray™ operates automatically and is dependent on pump
activation (or the filtration pump, where present) during the fil-
tering cycle, it remains off when the hydromassage, blower or even
just the spotlight are on (as it is presumed that there is somebody
in the tub); Clearray™ (where a filtering cycle is active) begins oper-
ating once again 40 minutes subsequent to switching off the afore-
mentioned functions.
key
Rapid Filtering ("Boost")
( "hydro" and "hydro+blower" versions only)
This is recommended after intensive use of the hot tub and/or is as-
sociated with chemical treatment of the water, to favour the disso-
lution of substances used for disinfection.
To activate this function, press and hold down the "Pump"
key for 5 seconds. The display will show the message boo.
28

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis