Electrical Connections; Water Connections - Jacuzzi experience ENJOY Vorinstallationsblatt

Vorschau ausblenden Andere Handbücher für experience ENJOY:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
24
check valve
25
gate valve (for emptying)
26
pre-filters (where present)
27
overflow
28, 29
ground drainage points
30
gate valves (for system maintenance)
31
gate valves (for suction balancing)
32
hose draining (areas at risk from ice)
Spa-pak "booster kit" (optional)
33

Water connections

I
The hosing system (including connectors, gate valves, etc.,
3-3a) for connecting the Minipool to the Spa-Pak and the compensa-
tion tank, must be set up by the installer.
I
The Customer must provide the ground drainage points (
3a, detail 28 and 29) of suitable dimensions, which can be inspected
for any cleaning, and to which the low-point drain ø 50 mm (
3-3a, detail 3), the loading/overflow of the compensation tank and the
drain from the filter are to be connected.
Spa-pak "booster kit": in the instance where a spa-pak "boost-
er kit" is also installed, it must be connected to the drainage sys-
tem; refer to the relative documentation.
CAUTION! Before preparing the ground drainage points,
consult the local authority for the regulations that control
the drainage of chemically treated water.
I
In particularly cold areas, to avoid the risk of any remaining water
freezing (water that may remain in hosing after emptying the system)
it is advisable to install valves for the complete drainage of hosing (
2-2a-3-3a, detail 31).
I
To fill the spa, you can use a garden hose, or provide connections to the
plumbing system of the home as shown in
IMPORTANT: the 3/4" solenoid valve on the compensa-
tion tank (for automatic filling of water level) must
always be connected to the water system that supplies
the system.
Any connections to the drinking water system (other than
the recommended ones) must be carried out according to
EN1717 regulations, using "AA", "AB" or "AD" anti-pollu-
tion protection procedures. For further information, we
recommend you contact your water supply company
and/or your plumber.
I
If included, connection of the blower (
spa must be made by creating a siphon (
near as possible to the spa itself. This will prevent situations where the
water might reach the blower and compromise its operation.
i
2-2a-
i
2-2a-3-
i
2-2a-
i
2-2a-3-3a, detail 11.
i
2-2a-3-3a, detail 17) to the
i
3-3a and 7, detail B) as

Electrical connections

I
For preparations/measuring the electric system that will supply the
spa, please note that powers in kW indicated in the "Maximum
Absorption of the System" table are to be considered as maximum
absorbed powers during operation.
Spa-pak "booster kit": in the instance where a spa-pak "boost-
er kit" is also installed, a separate supply line must be provided
and it must be connected to the main spa-pak; refer to the rela-
tive documentation.
SINGLE-PHASE BASE AND SINGLE-PHASE TOP (
The electric power supply may be provided by:
- single-phase line
The terminal block of the electrical box is setup for supply with
two single-phase lines (220-240 V 1N~).
NOTE: if power is supplied with a double mono-phase line
(220-240 V 1N~) or with a three-phase line with a neutral wi-
re (380/415 V 3N~) before making the connection, you will
need to remove the jumpers in the electrical box according to
the provided instructions and diagrams.
I
The installer must in any case use properly protected cables
with a suitable cross-section (see the minimum cross-sec-
tion tables), with characteristics not inferior to type H 05 VV-F
(multipolar).
• SINGLE-PHASE BASE VERSION
heater (3
(*)
220 - 240 1N~
380 - 415 3N~
(*): special standard (not valid for Europe)
i
• SINGLE-PHASE TOP VERSION
heater (3
(*)
220 - 240 1N~
380 - 415 3N~
(*): special standard (not valid for Europe)
THREE-PHASE TOP (
I
The installer must use cables with a suitable cross-section (see
the minimum cross-section tables) protected with a sheath of Ø
32 mm at the terminal in question and/or tubes or pipes when car-
rying out connection to the main switch with characteristics not
inferior to type H05VV-F (multipolar) or H07 V-K (unipolar).
• THREE-PHASE TOP VERSION
heater (12
220 - 240 3~
(*)
380 - 415 3N~
(*): special standard (not valid for Europe)
NOTE: The lead sections must take account not only the systems
absorption but also the cable path and the distances, the chosen
protection systems and the specific regulations for fixed electrical
systems in force in the country where the spa is installed.
21
without
with
heater
)
kW
4 mm
2
2,5 mm
2
2,5 mm
2
1,5 mm
2
without
with
heater
)
kW
4 mm
2
4 mm
2
2,5 mm
2
2,5 mm
2
i
5).
without
with
heater
)
kW
10 mm
2
2,5 mm
2
4 mm
2
1,5 mm
2
i
4).
with
heat exchanger
2,5 mm
2
1,5 mm
2
with
heat exchanger
4 mm
2
2,5 mm
2
with
heat exchanger
2,5 mm
2
1,5 mm
2