11. Mixing

A. Turn the speed drive switch to the ON
position.
B. Adjust the RPM with the RPM Regulator
Knob to desired speed.
C. Mix according to application
specifications.
Do not attempt to mix in empty or dry
Flexel
®
3D LevMix Bags for drums. It may
result in to damage of the film of the
®
Flexel
3D LevMix Bags for drums.
14
12. Removing Superconducting
Drive Unit from Tank
A. When mixing is complete, turn the RPM
Regulator to zero (0) and turn the drive
switch to the OFF position. (Ensure that
electrical power remains connected to the
machine when mixing multiple Flexel
LevMix Bags for drums consecutively.)
B. Firmly hold the drive unit handle and
raise the drive unit slightly to release the
locking lever. Release the locking lever by
pulling it toward the control box.
C. Carefully lower the rear wheels of the
drive unit to the floor and roll the drive unit
on its rear wheels away from the dolly.
D. Press down on the drive unit handle just
until the guide bearings are free from the
guide rails.
E. Pull the drive unit slightly farther away
from the dolly and carefully lower the front
wheel to the ground.
F. The tank can now be wheeled to another
station on the elevated dolly. The Supercon-
ducting Drive Unit remains ready for mixing.
G. To drain fluid from the Flexel
Bags for drums, unclamp the bottom drain
tube.
H. When the Flexel
®
3D LevMix Bags for
drums is completely drained, remove the
bag by carefully pulling the impeller seat
and the drain tube out of their respective
ports.
I. Remove the centering aligner from the
tank and return to the supplied Accessories
Box for future use. The Interface should
remain in its locked position for future use.
Always put the protective shield back on
the Flexel
®
3D LevMix Bag for drums before
disposal.
J. Dispose of bag.
Maintenance and Care of Superconducting
Drive Unit
The LevTech DB-200E Superconducting
Drive is designed to operate 24/7 mainte-
®
3D
nance free. However, to minimize the wear,
it is recommend that the drive be unplugged
if it is not in use for more than 24 hours.
Each time the drive is to be used, it is
necessary to charge the superconductors.
The drive should not operate continuously
for more than 10 days without recharging
the superconductors. To recharge supercon-
ductors the machine must be unplugged for
at least 25 minutes. Then follow charging
procedures in section 5.
®