Model
Alarm for oil pressure too low
Oil cooling
Total capacity of the cooling circuit
(excluding radiator and relevant pipes)
setting pressure of the expansion tank
plug
Coolant
Coolant maximum temperature alarm
Opening value (start/finish) of thermostatic
valve
Nominal voltage
Alternating current generator (nominal volt-
Alternating current generator (nominal cur-
Starter motor output
Recommended battery capacity
Battery breakaway current
Maximum depression allowed with new air
filter
TECHNICAL DATA (D754 TE3-SE3-IE3)
These technical data and specifications re-
fer exclusively to standard VM MOTORI
S.P.A. engines.
GB
English
D704 TE2
bar
0,4
COOLING CIRCUIT
litri
5
bar
1
Demineralised cold water 50% + Antioxidant and anti-freeze fluid 50% (Inhibited
glycol ethylene in compliance with ASTM D 3306)
°C
107
°C
80 (+/-2) / 95
ELECTRIC SYSTEM
V
12
V
14
A
55
kW
2,3
Ah
92
A
480
SUCTION CIRCUIT
mbar
15
- 18 -
D700/750 E2-E3
D754 E2
D754 TE2
0,4
0,4
Oil/water cooler
5
5
1
1
107
107
80 (+/-2) / 95
80 (+/-2) / 95
12
12
14
14
55
55
2,3
2,3
92
92
480
480
15
15
D706 IE2
0,4
7,5
1
107
80 (+/-2) / 95
12
14
55
2,3
100
550
15
IDM-45300900600.tif