17
Technical Information
TV 1001 Controller Installation

Connection A - High Vacuum Flange

For ISO-K flange connections, fix the two flanges with the clamps as
shown in the figure.
Figure 54
WARNING!
It is mandatory to connect the pump in such a way to withstand the torque
specified in the "IN-STRUCTION FOR USE" section. Specifically pay attention
to clamp design, material of clamps and bolts and bolt fixing torque
For ConFlat flange connections we recommend using Agilent
hardware.
To facilitate assembly and dismantling, apply Fel-pro C-100 high
temperature lubricant to the screw threads protruding from the
flange and between the nuts and flange.
Note that the connections can be made only with the bolt in the lower
side.
Attach the units and tighten each one in turn. Re-peat the sequential
tightening until the flange faces meet.