Supplement to operating instruction - ENGLISH
4.2.4
Installation for the WaveInjector WI-400x-xx-T
When measuring in diagonal arrangement, the tensioning screws of the pipe mounting fixtures point in opposite directions,
see Fig. 4.37.
When measuring in reflection arrangement, the tensioning screws of the pipe mounting fixtures point in the same direction,
see Fig. 4.38.
Fig. 4.37:
Installed pipe mounting fixture (diagonal arrangement)
1
1 – tensioning screw
Fig. 4.38:
Installed pipe mounting fixture (reflection arrangement)
1 – tensioning screw
2018-01-19, SUFLUXUS_WIV4-3EN
1
1
WaveInjector WI-400
77