go out. The device now switches auto-
8
matically into maintenance charging mode.
Mode 4
„12 V" (14.7 V / 3.8 A)
Q
This mode is used for charging 12 V lead-acid bat-
teries with a capacity greater than 14 Ah under
cold conditions or for charging some AGM (Absor-
bent Glass Mat) batteries with a capacity greater
than 14 Ah.
P ress the MODE selection button
mode 4. As you select the desired mode, the
appropriate LED indicator
mediately. if you take no further action, the elec-
tronic control switches on after a preset delay
to begin the charging process. in this mode the
charging current is the same as in "mode 3". if
the process runs without any problems, the LED
indicator
lights up, the electronic control
8
switches on and remains in this state until the
battery is charged. As soon as this point is
reached, the battery charger switches to main-
tenance charging mode. Now the LED indicator
goes out and the LED indicator
8
lights up to indicate the present status.
regenerating / charging
Q
empty (used, overcharged)
12 V batteries
The battery charger detects the battery voltage au-
tomatically once the battery charger is connected
to a battery and the charging process has started.
it changes to pulse charging mode if the voltage is
in the range of 7.5 V ± 0.5 to 10.5 V ± 0.5 V.
This pulse charging process is continued until the
battery voltage has increased to 10.5 V ± 0.5 V.
As soon as this state is reached, the battery charger
switches into the normal charging mode that you
selected earlier.
Now the battery can be charged quickly and safely.
Most empty batteries can be charged and used
again using this procedure.
Operation / Maintenance and care / Service
nOTe: The LED indicator
the pulse-charging process.
Q
As soon as a deviating situation, such as short-circuit,
critical voltage drop during the charging process,
open circuit or reversed connection of the output
clamps, occurs, the battery charger switches the
electronics off and resets the system directly into the
default settings to avoid causing any damage. if you
to select
do not activate any settings, the system will remain
9
in STANDBY mode. With the inverse connection of
lights up im-
the output clamps the LED display „incorrect polari-
5
ty / fault"
Q
if the appliance becomes too hot during charging,
the power output is automatically reduced. This
protects the appliance from damage.
Q
7
The appliance is maintenance-free.
Q

Protective function of the device

lights up additionally.
6

Overheating protection

Maintenance and care

Before you carry out any work
on the battery charger always pull the mains
plug out of the mains socket.
D o not under any circum-stances use solvents
or other aggressive cleaning agents.
S witch off the appliance.
C lean the plastic surfaces of the device with
a dry cloth.

Service

Have your device
repaired at the service centre or by
qualified specialist personnel using
original manufacturer parts only. This
will ensure that your device remains safe to use.
flashes during
8
GB
41