ZWEMBAD SERIES · AIR/WATER SYSTEM
Filter Control
ON / OFF.
Comfort Function
Enabled / Disabled
Cool
Enabled / Disabled
Heat+Cool Mode
Enabled / Disabled
Delay Time
XX min.
Sample Time
XX min.
Defrost Mode
1 / 2 / 3
© ZWEMBAD 2015. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
PARAMETERS OF THE TECHNICAL MENU: CONTINUATION 1
Filter control ON: The heat pump controls the purification
pump, control of water flow.
Filter control OFF: The heat pump does not control the
purification pump. Will only heat with external filtration.
Comfort function ENABLED: The user may choose
between the Comfort and Filtration functions.
Comfort function DISABLED: The heat pump is always
functioning in Filtration Mode.
This menu will only appear if the "Purification Control" is
activated.
Cool Mode ENABLED: The user may configure the
machine to heat or cool.
Cool Mode DISABLED: The user does not have control
over the functional mode of the machine, which will be to
heat.
This parameter only appears if the "4-way Valve"
parameter is activated in the manufacturer's menu.
Cool+Heat Mode ENABLED: The user may configure the
machine to heat and cool.
Cool+Heat Mode DISABLED: The user may configure the
machine to heat or cool.
This parameter only appears if the "4-way Valve"
parameter is activated in the manufacturer's menu and the
"Cool" parameter is activated.
The time lapse between when the machine should activate
and when it really does.
This menu only appears if the "Comfort Function" is
activated.
The temperature reading time is 5 minutes or until
programmed.
This menu only appears if the "Comfort Function" is
activated.
Depending on the installation, one of the following Defrost modes
may be selected:
o Fan Stop: By air without fan.
o Air + Fan: By air with fan on.
o Inverter: By inversion of the cycle.
This last mode is only available if the "4-way Valve" parameter is
activated in the manufacturer's menu.
ENGLISH