Repairs
Replacing valve set:
Fig. 5: Valve set
Procedure:
Counter spindle on the wrench flat using open-end wrench (WAF 7).
Carefully loosen centering using a suitable open-end wrench (WAF 5.5) to prevent damaging the
spindle thread.
Unscrew centering
WARNING!
Risk of damage if the wrong tools are used!
It is dangerous to use unsuitable tools for installation work as the device may be
damaged.
• To remove the centering from the spindle, use an open-end wrench, never a pipe
wrench.
48