Parameterizing Steps
Temperature
monitoring of the
motor
P380 /
P381 /
Sensor
°C
°C
= 0
= 0
KTY84 for RL
adapt.
= 0
= 1
PTC
= 1
= 0
PTC
= 1
= 1
PTC
= 0
> 1
KTY84
> 1
= 0
KTY84
> 1
> 1
KTY84
= 1
> 1
KTY84
> 1
= 1
KTY84
9-64
In exceptional cases this is not necessary:
♦ If P068 is only adjusted between 0 and 2 (dv/dt filter).
♦ If P340 is adjusted in integer increments, e.g. from 2.5 kHz to
5.0 kHz...7.5 kHz... etc.
♦ If P339 is not set to over-modulated space vector modulation; if
P339 = 4, 5 (over-modulated space vector modulation), the
overrange limit P342 must also be reduced to limit torque ripple and
motor heating.
♦ If changeover is made between speed and torque control
(P100 = 4, 5).
♦ If changeover is made between speed and frequency control and
the following parameters are adapted:
P315 = EMF Reg.Kp
P223 = Smooth.n/f(act)
P216 = Smooth. n/f(pre)
P222 = Src n/f(act)
The speed controller dynamic response may have to be reduced in the
case of encoder-less speed control (frequency control) (Reduce gain
(P235); increase Tn (P240)).
Activation of the measured value or PTC thermistor monitoring for the
motor causes different fault and alarm signals depending on the setting
of parameters P380 and P381. These are listed in the following table:
r009
Alarm A23 in
ready
if P386 =
-
2
no
-
1)
no
yes
1)
no
yes
yes
-
3)
yes
yes
3)
yes
yes
1)
no
yes
3)
no
yes
1) Alarm or fault are triggered on violation of the PTC thermistor temperature or on a
cable break (not a cable short circuit).
2) Fault is only triggered on cable break or cable short-circuit.
3) Fault or alarm on violation of the temperature limit..
4) Fault is only triggered on cable short-circuit.
f-control (P100 = 3)
2 x Kp
0 ms
4.8 ms
KK0000
Alarm A23 in
Fault F20 in
operation
ready
-
-
-
-
1)
yes
-
-
-
-
-
3)
yes
yes
3)
yes
yes
-
-
3)
yes
yes
6SE7087-6KD60
Operating Instructions
SIMOVERT MASTERDRIVES
04.2006
n-control (P100 = 4)
Kp
4 ms
0.0 ms
KK0000 (KK0091)
Fault F20 in
operation
-
1)
yes
-
1)
yes
3)
yes
4)
2)
yes
4)
3)
yes
3) 2)
yes
4)
2)
yes