Parameterizing Steps
Downloading with
the OP1S
Download with
DriveMonitor
9-40
The OP1S operator control panel is capable of upreading parameter
sets from the units and storing them. These parameter sets can then be
transferred to other units by download. Downloading with the OP1S is
thus the preferred method of parameterizing replacement units in a
service case.
During downloading with the OP1S, it is assumed that the units are in
the as-delivered state. The parameters for power section definition are
thus not transferred. (Refer to Section "Detailed parameterization,
power section definition")
Parameter number
P060
P070
P072
P073
Table 9-6
Parameters you cannot overwrite during download
The OP1S operator control panel also stores and transfers parameters
for configuring the USS interface (P700 to P704). Depending on the
parameterization of the unit from which the parameter set was originally
upread, communication between the OP1S and the unit can be
interrupted on account of changed interface parameters after
downloading has been completed. To enable communication to re-
commence, briefly interrupt the connection between the OP1S and the
unit (disconnect OP1S or the cable). The OP1S is then newly initialized
and adjusts itself after a short time to the changed parameterization via
the stored search algorithm.
With the aid of the DriveMonitor PC program, parameter sets can be
upload from the units, saved to the hard disk or to floppy disks, and
edited offline. These parameter sets, stored in parameter files, can then
be downloaded to the units again.
The offline parameter editing facility can be used to produce special
parameter files to suit a particular application. In such cases, the files
need not contain the full set of parameters but can be limited to the
parameters relevant to the application in question. For further
information, see under "Upload / Download" in the "Parameterization"
section.
Parameter name
Menu selection
Order No. 6SE70..
Rtd Drive Amps(n)
Rtd Drive Power(n)
Operating Instructions
04.2006
6SE7087-6KD60
Siemens AG
SIMOVERT MASTERDRIVES