11

Spare parts

12

Disposal

12.1

Oils and lubricants

12.2

Protective clothing

12.3
Information on the collection of
used electrical and electronic
products
Installation and operating instructions Wilo-EMU KS
Spare parts
⇒ Contact customer service.
4. There are only two phases at the connection.
⇒ Have the connection checked and corrected by a qualified electrician.
5. Incorrect direction of rotation.
⇒ Have the connection corrected by a qualified electrician.
6. Signs of wear on the hydraulics.
⇒ Have the components (impeller, suction port, pump housing) checked and re-
placed by customer service.
7. Motor bearings have worn.
⇒ Inform customer service; send the pump back to the factory for overhauling.
8. Pump is installed under tension.
⇒ Check installation, install rubber compensators if necessary.
Fault: Sealing chamber control reports fault or switches the pump off
1. Condensation water build-up due to extended storage or high temperature fluctu-
ations.
⇒ Operate the pump for a short period (max. 5 min.) without pencil electrode.
2. Increased leakage when running in new mechanical seals.
⇒ Change the oil.
3. Pencil electrode cable is defective.
⇒ Replace the pencil electrode.
4. Mechanical seal is defective.
⇒ Inform customer service.
Further steps for troubleshooting
If the points listed here do not rectify the fault, customer service must be contacted.
Customer service can provide the following remedies:
▪ Telephone or written support.
▪ On-site support.
▪ Inspection and repair of the pump at the factory.
Costs may be incurred if other services of the customer service are availed! For more
details, please contact customer service.
Spare parts are ordered via customer service. To avoid return queries and incorrect or-
ders, the serial or article number must always be supplied. Subject to change without
prior notice!
Operating fluid must be collected in suitable tanks and disposed of in accordance with
the locally applicable guidelines.
Used protective clothing must be disposed of in accordance with the locally applicable
guidelines.
Proper disposal and appropriate recycling of this product prevents damage to the envir-
onment and danger to your personal health.
NOTICE
Disposal in domestic waste is forbidden!
In the European Union, this symbol can appear on the product, the packaging or the
accompanying documentation. It means that the electrical and electronic products
in question must not be disposed of along with domestic waste.
To ensure proper handling, recycling and disposal of the used products in question,
please note the following points: