Possible faults

Before each fault elimination:
 Switch off device.
 Pull out power plug
Problem
Logs are not being split properly
(insufficient splitting performance)
Splitting blade extends wobbling or
with strong vibrations
Splitting blade does not extend
Motor starts, but the splitting blade
does not extend
Motor does not start
In case of further faults or inquiries please contact your local dealer.
Possible Cause
 The log is not positioned correctly
 The log exceeds the maximum
dimensions or the wood is too hard
for the performance of the machine
 Splitting blade does not split log
 Oil leak
 Hydraulic pressure too low
 Incorrect connecting lead (longer
than 10 m or too small cable cross-
section).
 Air in the circuit
 Splitting column not sufficiently
lubricated or oiled
 Hydraulic pump defective
 Motor turns in wrong direction
 No power supply.
2-phase mode in threephase mo-
tor.
 Mains cable defective.
 Electric motor defective
Remedy
 Reposition the log correctly
 Cut the log to the required dimensions
 Sharpen splitting blade, check for burrs or notches
 Place a sheet of cardboard under the log splitter in
order to locate the leak. To correct the problem, re-
fer to the manufacturer
 Check the oil level and add more oil if necessary
If the problem cannot be rectified, refer to the man-
ufacturer
 Use the correct connecting lead
 Open oil tank cap
 Check the oil level and add more oil if necessary
 Lubricate splitting column or oil with environmental-
ly friendly spray oil.
If the problem cannot be rectified, refer to the man-
ufacturer
 To correct the problem, refer to the manufacturer
 Check the motor direction
Threephase: adjust the motor direction
 Check fuses.
Have fuse and lead checked by qualified electri-
cian.
 Replace the connection cable or have it checked by
an electrician
 To correct the problem, refer to the manufacturer