Transport instructions

Before each transport
 Retract the splitting column
 Switch off device.
 Close the oil cap.
 Pull out power plug
 Remove the split wood
To transport the machine, grasp the handle (14) and tilt
the log splitter slightly towards you. The log splitter can be
easily transported in this position.
Use the lifting point (A) provide for transport with a
crane.
 Secure the device against tipping over or sliding away when
transporting it by crane.
 When transporting the product within a car put it in the boot
or on a separate loading area.
While doing so, secure the log splitter at the points
provided with straps.

Possible faults

Before each fault elimination:
 Switch off device.
 Pull out power plug
Problem
Logs are not being split properly
(insufficient splitting performance)
Splitting column moves unsteadily
or with strong vibrations.
Splitting column does not move in.
Motor does not start
In case of further faults or inquiries please contact your local dealer.
Possible Cause
 The log is not positioned correctly
 The log exceeds the maximum
dimensions or the wood is too hard
for the performance of the machine
 Splitting blade does not split log
 Oil leak
 Hydraulic pressure too low
 Incorrect connecting lead (longer
than 10 m or too small cable cross-
section).
 Air in the circuit
 Splitting column not sufficiently
lubricated or oiled
 Hydraulic pump defective
 No power supply.
 Mains cable defective.
 Electric motor defective

Storage

Before each storage
 Retract the splitting column
 Switch off device.
 Close the oil cap
 Pull out power plug
Store machines that are not in use in a dry locked place pro-
tected against frost and outside the reach of children and unau-
thorized persons.
Before extended storage, please observe the following to in-
crease the service life of the device and to ensure smooth
operation:
Thoroughly clean the device.
Check the device for damaged or worn parts.

Guarantee

Please observe the enclosed terms of guarantee.
Remedy
 Reposition the log correctly
 Cut the log to the required dimensions
 Sharpen splitting blade, check for burrs or notch-
es
 Place a sheet of cardboard under the log splitter
in order to locate the leak. To correct the prob-
lem, refer to the manufacturer
 Check the oil level and add more oil if necessary
If the problem cannot be rectified, refer to the
manufacturer
 Use the correct connecting lead
 Open oil tank cap
 Check the oil level and add more oil if necessary
 Lubricate splitting column or oil with environmen-
tally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer
 To correct the problem, refer to the manufacturer
 Check fuses.
 Replace the connection cable or have it checked
by an electrician
 To correct the problem, refer to the manufacturer