Herunterladen Inhalt Inhalt Diese Seite drucken

Wilo Helix VE 52 Einbau- Und Betriebsanleitung Seite 43

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.2
Technical data
Maximum utilisation pressure
Pump housing
Maximum suction pressure
Temperature range
Fluid temperature
Ambient temperature
Electrical data
Motor efficiency
Motor protection rating
Insulation class
Frequency
Power supply voltage
Types of supported power supplies
Other characteristics
Ambient humidity
Altitude
Max. suction height
Noise level dB(A)
0/+3 dB(A)
Power supply cable cross section
diameter (cable equipped
with 4 wires) mm
2
- Electromagnetic compatibility
• Residential emission –
1st environment:
• Industrial interference resistance –
2nd environment:
(*) In the frequency range between 600
display or the pressure indication in the display might be
disturbed in the exceptional case of the direct vicinity
(<1 m from the electronic module) of radio transmission
installations, transmitters or similar devices working in
this frequency range. The operation of the pump is not
affected at any time.
Installation and operating instructions – HELIX­VE 22­36­52
16, 25 or 30 bar depending on the model
10 bar
Notice: the actual input pressure (P input) + the pressure at zero delivery
rate (P zero delivery rate) must always be lower than the maximum
authorised operating pressure (Pmax). If the maximum authorised
operating pressure is exceeded, the mechanical seal and the roller
bearing can be damaged or their life span reduced.
P input + P zero delivery rate ≤ Pmax
Refer to the pump plate for the maximum operating pressure: Pmax
-20°C to +120 °C
-30°C to +120° C (if full stainless steel)
-15°C to + 90°C (Viton version for O'ring and mechanical seal)
-15°C to +50 °C On request for other temperature
IE4
IP55
155 (F)
See motor plate
0.55 0.75 1.1 1.5 2.2 3
TN, TT
< 90 % without condensation
< 1000 m (> 1000 m on request)
Depending on NPSH of the pump
0.55 0.75 1.1 1.5 2.2 3
61
63
0.55 0.75 1.1 1.5 2.2 3
1.2
1.5­2.5
(*)
PN­EN 61800­3
PN­EN 61800­3
 
 
MHz and 1
GHz, the
Power (kW)
4
5.5 7.5 11 15 18.5 22
400 V (±10 %) 50 Hz
380 V (±10 %) 60 Hz
480 V (±10 %) 60 Hz
Power (kW)
4
5.5 7.5 11 15 18.5
67 71 72
74
Power (kW)
4
5.5
7.5 11
2.5 – 4
2.5 – 6 4 – 6 6 – 10
- Outline and connection dimensions (Fig. 4).
5.3
Scope of delivery
• High-pressure multistage centrifugal pump.
• Operating manual.
22
78
81
15
18.5
22
10 – 16
English
43

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis