9.1 Maintenance intervals

NOTICE
• The specified maintenance intervals are guidance values and refer to single-shift
operation.
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection
and testing, as well as any national laws and regulations.
Check the following:
Several times a day
Clean weld spatter from the torch head. In
the case of heavy weld spatter build-up,
clean during each welding break.
• Clean the ROBO Compact W600
using an ABICOR BINZEL torch
cleaning station. Then spray with
ABICOR BINZEL anti-spatter fluid.
Tab. 11
Maintenance and cleaning
9.2 Wire guide
Each time the wire guide is changed (liner, PA liner), make sure to consult the product
information in the instruction leaflets provided.
BAL.0374.0 • 2019-04-01
Weekly
We recommend basic cleaning
once a week. The type and
frequency of cleaning shall be
determined and established by
the operator of the welding
system.
Optional wire brake
• Clean the wire brake once
or twice, depending on wire
quality.
 9.5 Cleaning the wire
brake (optional version
with wire brake) on
page EN-22
9 Maintenance and cleaning
Monthly
• Check that the
connections (cable
assembly, control lead,
ground) are secure.
Tighten if necessary.
EN - 19