and the contact bridges inserted or
removed (see following figures).
– When connecting the appliance, VDE
requirements and the 'Technical connec-
tion requirements' must be observed.
Contact protection must be guaranteed.

Connecting to the mains

Selection of the type of network cable
depends on the connection type (see circuit
diagrams).
1. Before accessing the terminals, switch
off all supply circuits and secure them
against being switched on again.
2. Make sure that all poles of the connection
cables are disconnected and that effec-
tive earthing is possible.
3. Connect the wires and, if necessary,
the enclosed brass bridges to the corre-
sponding contact terminals of the cooker
power connection in accordance with the
circuit diagrams shown here.
4. Lay the connection cable behind the
stove so that it does not touch the rear
wall of the cooker. The rear cooker wall
becomes hot while it is in use.
5. Check all connections comply with VDE
0701.
Fitting and installation
Connection types
L1 – L3: Phase(s)
N: Neutral conductor
PE: Protective conductor (earth wire)
220-240 V 1N~ 50/60 Hz
L1 to
  
3
4
N to
 
2
5
N
Protective conductor (PE)
1
L1
PE
to
Mains connection:
H05VV-F, 3 x 6 mm
380-415 V 2N~ 50/60 Hz
L1 to
 
3
4
L2
L2 to
2
5
L1 N
N to
 
1
PE
Protective conductor (PE)
to
Mains connection:
H05VV-F, 4 x 4 mm
380-415 V 3N~ 50/60 Hz
L1 to
, L2 to
3
4
L3
N to
 
2
5
L2
N
Protective conductor (PE)
1
L1
PE
to
Mains connection:
H05VV-F, 5 x 2.5 mm
Page GB-25
(bridged)
(bridged)
2
(bridged)
(bridged)
2
, L3 to
(bridged)
2