Page GB-24
Fitting and installation
4. Use the supplied retaining clamps f and
screws g to fix the hob in place to the
worktop and to prevent it from slipping.
Power supply – notes for the
electrician
WARNING
Electric shock / fi re hazard!
Improperly installed electrical
connections can cause electri-
cal shocks and/or short circuits.
Connection to the mains supply may
only be made by an authorised elec-
trician approved by the local energy
supply company, e.g. our Service Cen-
tre (see „Our Service Centre" on page
GB-28). Only then will you benefi t from
our warranty and a suffi cient level of
safety.
Since all poles of the appliance can-
not be disconnected from the mains
via an accessible disconnecting de-
vice, an all-pole disconnecting device
in accordance with overvoltage cat-
egory III must be connected within
the house installation with at least
3 mm contact clearance; this includes
fuses, miniature circuit breakers and
protective devices.

Connection conditions

The oven is designed for the following alter-
nating voltages:
– 220-240 V 1N~ 50/60 Hz
– 380-415 V 2N~ 50/60 Hz
– 380-415 V 3N~ 50/60 Hz
– A separate power supply is required.
– The power cable used must comply with
the requirements of DIN EN 60335-1 (e.g.
type H05RR-F, H05VV-F).
– Depending on the type of connection, the
conductor cross-section must be selected