Switching on and off

During operation, you can choose between instan-
taneous and continuous operation .
Switching to instantaneous operation:
Press the ON/OFF switch
Switching off instantaneous operation:
Release the ON/OFF switch
Switching to continuous operation:
Press the ON/OFF switch
position with the locking switch
Switching off continuous operation:
Press the ON/OFF switch
again .

maintenance and cleaning

WArnInG! rISk of Injury! Switch
off the appliance and pull out the
power plug before starting any work
on the appliance.
The handles, ventilation slots and the motor
housing must always be kept clean, dry and
free from oil or grease .
Use a soft, dry cloth to clean the housing .
Make sure that the ventilation slits are not
obstructed .
Clean the tool holder
Before fitting a tool into the tool holder
grease it lightly .
WARNING!
If the cord of the power tool is damaged, it
must be replaced with a specially designed
cord that can be purchased through our
Customer Service .
NOTE
Replacement parts not listed (such as switch-
es) can be ordered via our service hotline .
PAH 1700 A1
.
.
and lock it in this
.
and release it
regularly:
,

Topping up the oil

NOTE
Before operating the appliance, check
whether there is enough oil in the appliance
(see section "Checking the oil level") .
Operation without sufficient oil will cause
irreparable damage to the appliance .
If you have ascertained that there is no oil in the oil
inspection window
, you need top up the oil:
Lay the appliance on a flat surface with the oil
inspection window
Use the supplied assembly wrench
remove the oil inspection window
housing .
Pour the oil with help from the oil bottle
the opening until it is 1 cm below the lip .
Replace the oil inspection window
screw it tight using the assembly wrench
Check the fill level as described in the section
"Checking the oil level" .

Replacing the carbon brushes

NOTE
Have the carbon brushes replaced by the
manufacturer, Customer Service or a similarly
qualified person .

Disposal

The packaging is made of environmentally
friendly material and can be disposed of
at your local recycling centres .
Do not dispose of power tools in
your normal domestic waste!
European Directive 2012/19/EU requires that
worn-out power tools be collected separately and
recycled in an environmentally compatible manner .
Your local community or municipal authorities can
provide information on how to dispose of the worn-
out appliance .