Herunterladen Inhalt Inhalt Diese Seite drucken

Parkside PPS 40 A1 Bedienungs- Und Sicherheitshinweise Und Originalbetriebsanleitung Seite 17

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Troubleshooting
Faults
Indicator lamp
does not lit up?
Ventilator does
not work?
Warning lamp
switches on?
No output
current?
Output current
does not
decrease?
Air current cannot
be regulated?
HF-arc is not
created?
Bad ignition?
Pistol is not ready
for operation
Cause of fault
No electrical connection
ON/OFF switch set to off
Power line interrupted
Power line ventilator faulty
Ventilator faulty
Overheating protection
switched on
Input voltage too high
Machine faulty
Overvoltage protection
activated
Input voltage too low
Connection cable cross-section
too low
Compressed air hose
damaged or faulty
Valve/manometer fails
The burner switch is faulty
Soldering point on the burner
switch or plug loosened
Valve/manometer fails
Burner wear parts damaged
or worn
Check HF spark gap
Current switch is switched off
Air transmission is restricted
Workpiece is not connected to
the ground terminal.
Troubleshooting
Troubleshooting
Check power cable
Set switch to ON
Check power line
Allow device to cool down
Input voltage according
to type plate
Machine must be repaired
Allow device to cool down
Observe input voltage
according to type plate
New connection of the hose
Renew electrode
Change wear parts
Set spark gap
Switch the current switch to
'on'
Another indication of this is
a green flame. Check the air
supply.
Check the connection.
GB/MT
77

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading