RID14
Installation
4.3
Mounting instructions
The device can be mounted directly on the wall. A mounting bracket is available for pipe
mounting (→ å 4). The illuminated display can be mounted in four different positions
(→ å 3).
4.3.1 Rotating the display
Pos. 1
4
3
Pos. 2
Pos. 3
Pos. 4
2
90°
1
90°
90°
a0011256
Fig. 3: Field indicator wall mounting, 4 display positions, can be plugged in in stages of 90°
The display can be turned in stages of 90°. First remove the cover clamp (1) and the housing
cover (2). Then remove the display (3) from the electronics unit (4). For configuration purposes,
the ribbon cable between the display and electronics unit has to be plugged in.
Turn the display to the desired position and then attach it to the electronics unit.
4.3.2 Direct wall mounting
Proceed as follows to mount the device directly on the wall:
• Drill 2 holes
• Attach the device to the wall with 2 screws (∅5).
4.3.3 Pipe mounting
The mounting bracket is suited for pipes with a diameter between 1.5" - 3.3".
Proceed as follows to mount the device on a pipe:
• Attach the mounting bracket to the pipe
• The additional mounting plate must be used for pipes with a diameter of 1.5" to 2.2".
• Fix the device to the mounting bracket with the two screws supplied. The mounting plate is
not needed for pipes with a diameter of 2.2" - 3.3".
Endress+Hauser