Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - clage MBX 6 Shower Gebrauchs- Und Montageanleitung

E-kleindurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
MBX 4..7 Shower

3. Technical specifications

Type
Art. No.
Energy efficiency class
EN
Capacity
Nominal pressure
Heating system
Required water resistance
at 15 °C
Electric supply
Nominal power rating
Nominal current
Temperature choice
Factory temperature setting
Maximum inlet temperature
Factory flow setting at 3 bar
Maximum temperature increase
at rated power and a flow rate
of...
2)
Required l/min to switch on
Required l/min to switch off
Min. required cable size
Weight filled with water
Dimensions (H × W × D)
Protection class acc. to VDE
Type of protection according to VDE
* ) The declaration complies with the EU regulation No 812/2013. The product data sheet is attached at the end of
this document.
1) Without tap
2) Temperature rise (Kelvin) + cold-water temperature = maximum hot-water temperature (°C) ≤ 55 °C
3) The cable size must not exceed 4 mm
liter
MPa (bar)
Ω cm
1)
2.0 l/min
2.5 l/min
3.0 l/min
3.5 l/min
4.0 l/min
l/min
l/min
3)
mm
2
2
MBX 4 Shower
MBX 6 Shower
1500-15314
1500-15316
Bare wire heating system IES ®
≥ 800
1/N/PE ~ 220 V – 240 V
4.4 kW
19 A
30 – 45 °C
31 K
25 K
21 K
18 K
16 K
1.5
1.3
2.5
approx. 1.5 kg
13.5 × 18.6 × 8.7 cm
18
MBX 7 Shower
1500-15317
* )
A
0.2
1 (10)
≥ 800
≥ 1100
2/PE~ 400 V
5.7 kW
6.5 kW
25 A
16 A
45 °C
70 °C
5 l/min
41 K
46 K
33 K
37 K
27 K
31 K
23 K
26 K
20 K
23 K
1.5
1.5
1.3
1.3
4.0
2.5
1
IP 25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mbx 7 showerMbx 4 shower

Inhaltsverzeichnis