7. Electrical connection
6

8. Purging

To prevent damage to the appliance, the instantaneous water heater must be purged of
air before using it for the first time.
Each time it is emptied (for example after work on the plumbing system or following repair
work on the appliance), the instantaneous water heater must be purged before it is used again.
1. Switch off the power supply to the instantaneous water heater.
2. Unscrew the shower head
3. To purge the instantaneous water heater, open the tap in cold position first and after that in
hot position and wait until the water emerges free of air bubbles.
4. Switch the power supply back on again.

9. Commissioning

Do not switch on the electric power at this time!
1. Purge the appliance according to chapter "8. Purging".
2. Now close the circuit breaker to connect the electrical supply. After a short power-up delay
of approx. 12 seconds, the water heats up.
3. Explain the functions of the heater to the user and ensure that he knows how to use it.
Hand over these operating instructions to the user.
4. Use the registration card for the registration at the factory service centre or register the
appliance online on the website www.clage.com.
( 230 V~ )
MBX 4..6 Shower
( 400 V 2~) MBX 7 Shower
1
3
2
23
Circuit diagram
1. Electronic regulator
2. Heating element
3. Safety thermal cut-out