Herunterladen Inhalt Inhalt Diese Seite drucken

Adjusting The Water Flow; Adjusting The Water Temperature - clage MBX 6 Shower Gebrauchs- Und Montageanleitung

E-kleindurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

11. Adjusting the water flow

May only be carried out by a specialist.
Remove the cover (see Fig. 11), undo the hood screw underneath and remove the hood.
Decreasing the flow rate:
Turn the adjusting screw clockwise to decrease the flow rate, thus making a higher outlet tem-
perature possible.
Increasing the flow rate:
Turn the adjusting screw counter-clockwise to increase the flow rate, thus reducing the pos-
sible outlet temperature.
9
Direction

12. Adjusting the water temperature

10
Tem pe ra ture
Flow
in crease
+
+
25
The factory set hot water outlet temperature
is 45 °C.
This factory setting can be modified within
the range of approx. 30 °C to 45 °C by turn-
ing the readout potentio meter with a slotted
screwdriver (width approx. 2 mm).
The hot water outlet temperature will
be decreased by clockwise rotation and
increased by counterclockwise rotation.