technical information
energy monitor
End user can monitor accumulated*1 'Consumed electrical energy' and 'Delivered heat energy' in each operation mode*2 on the main remote controller.
*1 Monthly and Year to date
*2 - DHW operation
- Space heating
- Space cooling
Refer to "5.8 Main remote controller" for how to check the energy, and "5.1 DIP switch functions" for the details on DIP-SW setting.
Either one of the following two method is used for monitoring.
note: Method 1 should be used as a guide. if a certain accuracy is required, the 2nd method should be used.
1. Calculation internally
Electricity consumption is calculated internally based on the energy consumption of outdoor unit, electric heater, water pump(s) and other auxiliaries. (*3)
Delivered heat is calculated internally by multiplying delta T (Flow and Return temp.) and flow rate measured by the factory fitted sensors.
Set the electric heater capacity and water pump(s) input according to indoor unit model and specs of additional pump(s) supplied locally. (Refer to the menu tree in "5.8
Main remote controller")
Booster heater1
Default
EHST20C-VM2C
EHST20C-VM6C
EHST20C-YM9C
EHST20C-TM9C
EHST20C-VM2EC
EHST20C-VM6EC
EHST20C-YM9EC
EHST20C-MEC
EHST20D-VM2C
EHST20D-MEC
EHST20D-MHC
EHST20D-VM2EC
EHST20D-YM9C
ERST20C-MEC
ERST20C-VM2C
ERST20D-MEC
ERST20D-VM2C
EHPT20X-VM2C
EHPT20X-VM6C
EHPT20X-YM9C
EHPT20X-TM9C
EHPT20X-MHCW
EHST20C-MHCW
EHST20D-MHCW
*1 Change setting to 3kW when connecting optional immersion heater "PAC-IH03V2-E".
*2 "***" displayed in the energy monitor setting mode means the factory fitted pump is connected as Pump 1 so that the input is automatically calculated.
*3 When the cylinder unit is connected with a PUHZ-FRP or PUMY models, electricity consumption is not calculated internally. To display the electricity consumption,
conduct the 2nd method.
When anti-freeze solution (propylene glycol) is used for primary water circuit, set the delivered energy adjustment if necessary.
For further detail of above, refer to "5.8 Main remote controller".
2. Actual measurement by external meter (locally supplied)
FTC has external input terminals for 2 'Electric energy meters' and a 'Heat meter'.
If two 'Electric energy meters' are connected, the 2 recorded values will be combined at the FTC and shown on the main remote controller.
(e.g. Meter 1 for H/P power line, Meter 2 for heater power line)
Refer to the [Signal inputs] section in "5.2 Connecting inputs/outputs" for more information on connectable electric energy meter and heat meter.
Booster heater2
2kW
4kW
2kW
0kW
2kW
4kW
3kW
6kW
3kW
6kW
2kW
0kW
2kW
4kW
3kW
6kW
0kW
0kW
2kW
0kW
0kW
0kW
0kW
0kW
2kW
0kW
3kW
6kW
0kW
0kW
2kW
0kW
0kW
0kW
2kW
0kW
2kW
0kW
2kW
4kW
3kW
6kW
3kW
6kW
0kW
0kW
0kW
0kW
0kW
0kW
immersion
Pump1*2
heater*1
0kW
***(factory fitted pump)
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
3kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
0kW
***
3kW
***
3kW
***
3kW
***
<Table 3.6>
Pump2
Pump3
0kW
0kW
When additional pumps supplied locally are
connected as Pump2/3, change setting ac-
cording to specs of the pumps.