Herunterladen Inhalt Inhalt Diese Seite drucken

Nice Neoplus ML Anweisungen Und Hinweise Für Die Installation Und Die Bedienung Seite 3

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
2.1) Electrical connections
For motor connections, an omnipolar disconnecting device with a 3-mm minimum distance between contacts must
be provided for disconnection from the mains power supply (disconnecting switch or plug and socket, etc.).
Carefully follow all the connection instructions. If you have any doubts do not make experiments but consult the rel-
evant technical specifications which are also available on the web site "www.niceforyou.com".
An incorrect connection may be dangerous and cause damage to the system.
The cable used for the electrical connections of the NEOPLUS-M and NEOPLUS-L motors has 6 wires; 3 of the wires (yellow tag) are for the
mains power supply and 3 wires (green tag) are for the command signals.
For the electrical connections see the diagram below. The connection devices are not supplied with the product.
2.1.1) Mains power supply (Brown + Blue + Yellow/Green):
The mains power supply must be connected to the following wires: Brown (Phase); Blue (Neutral) and Yellow/Green (Ground).
Do not connect the mains power supply (230V or 120V) to the other wires.
2.1.2) "Step-by-Step" input (White + Black/White):
To manually command the automation system, a simple button can be connected between the White wire (Step-by-Step input) and the
Black/White wire (Common). The operating method follows the sequence: up-stop-down-stop.
If the button is kept pressed for more than 3 seconds (but less than 10) an up manoeuvre is always carried out (corresponding to the ▲ button
on the transmitters). If the button is kept pressed for more than 10 seconds a down manoeuvre is always carried out (corresponding to the ▼,
button) This function can be used to "synchronise" multiple motors to carry out the same manoeuvre, regardless of their operating status.
2.1.3) TTBUS" input (White + Black/White):
"TTBUS" is a Bus that was developed to control individually motors or control units, up to 255 devices by simply connecting them in paral-
lel with just 2 wires. Further information is contained in the instructions for the remote controls via "TTBUS".
The TTP or TTI programmers can be connected to the TTBUS input making the system management and programming operations easier;
for further information, consult the related manuals.
2.1.4) "Weather sensors" input (Orange/White + Black/White):
A simple wind sensor (anemometer) can be connected to the "Weather sensors" input between the Orange/White wire (Weather sensors
input) and the Black/White wire (Common): VOLO, or special wind-sun sensors VOLO-S e VOLO-ST; or wind-sun-rain sensor VOLO-SR.
The same sensor can control up to 5 motors or control units, which are all connected in parallel. It is essential that the polarity is respected:
on the motors, the Black/White wire is connected to the Black/White wire and the Orange/White wire is connected to the Orange/White wire.
2.2) Cable output direction
(this chapter concerns the NEOPLUS L version only).
If it is necessary to change the cable output direction, simply:
1. Pull the protection outwards.
2. Bend the cable in the required direction.
3. Introduce the protection, making sure that it is securely pushed
into its location.
Yellow label
Green label
L
N
Wire colouring
Mains power supply
Brown
Blue
Yellow/Green = Earth
Command signals
Black/White
White
Orange/White = Weather sensors
= Phase
= Neutral
= Common (0V)
= Step-by-St. + "TTBUS"
3
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis