Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS 21M-UUI-RP30-S4 Betriebsanleitung Seite 41

Optoelektronische sensoren
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IO-Link interface (continued)
System commands
Index
Name
Data
(dec.)
format
0x0002
System
UINT8
(2)
Command
Access
Value range
W
0x01 (1) =
ParamUploadStart
0x02 (2) =
ParamUploadEnd
0x03 (3) =
ParamDownloadStart
0x04 (4) =
ParamDownloadEnd
0x05 (5) =
ParamDownloadStore
0x06 (6) =
ParamBreak
0x40 (64) =
Teach Apply
0x41 (65) =
SP1SingleValueTeach
0x42 (66) =
SP2SingleValueTeach
0x43 (67) =
SP1TwoValueTeachTP1
0x44 (68) =
SP1TwoValueTeachTP2
0x45 (69) =
SP2TwoValueTeachTP1
0x46 (70) =
SP2TwoValueTeachTP2
0x47 (71) =
SP1DynamicTeachStart
0x48 (72) =
SP1DynamicTeachStop
0x49 (73) =
SP2DynamicTeachStart
0x4A (74) =
SP2DynamicTeachStop
0x4F (79) = Teach Cancel
0x80 (128) =
Device Reset
0x82 (130) =
Restore Factory Settings
0xA2 (162) =
Reset BDC
0xA5 (165) =
Maintenance Reset
0xA6 (166) =
Reset Counter
Comment
Block
Start Parameter Upload
parameterization
Stop Parameter Upload
Start Parameter Download
Stop Parameter Download
Stop block parameter
download and set Upload
Request
Abort block parameterization
Teach Channel
Reset
Device Reset
Reset sensor parameters to
factory defaults
BDC addressed by teach-in
channel to factory defaults
Maintenance - reset operating
hours counter to 0
Reset counter value
english