4.5. Continuity test
1. Connect the black test lead to the COM-jack and the red
test lead to the V//mA-jack. (Note: The polarity of the
red lead connection is positive "+")
2. Set the function switch to
3. In continuity testing if continuity exists (i.e. resistance
less than about 50) built-in buzzer will sound.
CAUTION! Never perform a continuity measurement on a
circuit that has power connected!
4.6. Diode
1. Connect red test lead to "V//mA" jack, black test lead
to "COM" jack.
2. Set the FUNCTION switch to the
and connect the red test leads to the anode of diode and
black to cathode. The display will then show the approx.
forward voltage of this diode. If connect the test leads on
the other way round, the display will show an overrange
status "1"
)
)
)
/Diode position.
°