Herunterladen Inhalt Inhalt Diese Seite drucken

Overheating Safety Feature; Power Surges - Teka VT TC 2P.1 Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 82
accidentally left on, they will be disconnec-
ted automatically after a certain amount of
time has passed since the last action using
the element. (See table 4)
Table 4
Level
MAXIMUM OPERATION
TIME (in minutes)
selected
INDUCTION HOTPLATES
1
2
3
4
5
6
7
8
9
10
11
12
When the "safety cut-off" has occurred, the
residual heat indicator H of the correspon-
ding heating element will appear in the
power indicator if there is a risk of burn.
0
Otherwise, a
will be shown.
SAFETY IN CASE OF COVERED SEN-
SOR BUTTONS
The touch control panel has a function that
makes it so the device automatically
detects when there is an object (cookware,
rag or spilled liquids) covering the panel
sensor buttons. This makes it possible to
prevent the object from activating or deac-
tivating a heating element without you rea-
lising it.
When the touch control panel disconnects
the device for safety reasons, it begins to
beep and it shows an error message until
the object covering the control panel is
removed.
If the touch control panel is in stand-by
mode, it will not detect the presence of an
object on it; nonetheless, to be able to acti-
vate the control panel, it is necessary to
remove the object on the control panel
beforehand.

Overheating safety feature

636
The induction areas are protected against
520
overheating that may cause damage to the
424
electronic system.
353
309
The induction generator has three mecha-
nisms which become active if the tempera-
260
ture rises too high in order to protect the
225
electronic components.
192
164
- The inner fan activates to cool the elec-
139
tronic area.
113
- The power level assigned to the cooking
area is adjusted.
90
- The relevant cooking area is switched off.
The internal fan is automatically enabled
and disabled, depending on the tempera-
ture of the electronic system. Therefore,
the fan may continue to work for a few
minutes to cool the electronics if you
switch the cooker off when the fan is swit-
ched on.
If an induction cooking area were to switch
off due to overheating, when restarted, the
power level selected would be re-enabled.
certain degree of power surges in the
electricity supply. Abnormally high
power surges can cause the control
system to malfunction (as with any type
of electrical appliance).

Power surges

Touch controls can withstand a
GB
75

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tr 3220Vi tc 30 2iVt cm 30 2p

Inhaltsverzeichnis