Alignment of the infrared sensor

1a
2
1. a)
Loosen locking screw on the underside of the sensor hood
using the Allen key (size 2) provided (3 rotations)�
b)
Turn the hood upwards and remove to the side�
2. Align the sensor further downwards:
shift stop pin as required in clockwise direction�
Align the sensor further upwards:
shift stop pin as required in anticlockwise direction�
3. a)
Position sensor hood (sensor window gently tilted
upwards) and rotate clockwise until the stop�
b)
Then tighten the locking screw by hand�
1b
2
1
3a
1
2
Washbasin fitting
!
If the installation deviates
from the recommended
assembly height, re-adjust-
ment of the sensor handle
is possible.
3b
WimTec ECOSAN W6
EN
31