Description of the functions

Warm water rinse:
DIP switch 4
Serves to rinse the warm water pipe without the need for
you to remain within the sensor range of the shower.
DIP switch 4 ON = Warm water rinse function enabled
(default setting).
DIP switch 4 OFF = Warm water rinse function disabled.
User detection
When you step in front of the
shower, the system will detect
you.
60 cm
60 cm
60 cm
60 cm
60 cm
PROOF P6 with thermal disinfection
Operation
After activation, water will
flow for 30 s plus the configu-
red shut-off delay without the
need for you to remain within
the sensor range; it will then
automatically shut down again.
If you enter the sensor range
for at least 5 s during these
30 s, the shower will resume
normal operation.
SanTec OCEAN P6 with thermal disinfection
Shower control
ON
It is recommended not to
OFF
1 2 3 4 5 6
combine the warm water
rinse with the fully automa-
tic program mode!
EN
Warmlauf:
ON
OFF
1 2 3
4
5 6
Reinigungsstopp:
ON
OFF
1 2 3 4
5
6
Hygienespülung:
ON
OFF
1 2 3 4 5
6
Halbautomatik:
ON
OFF
1 2
3 4 5 6
i
Vollautomatik:
ON
OFF
1 2
3 4 5 6
Manuell:
ON
OFF
1 2
3 4 5 6
31