Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Configuring the functions

ON
OFF
1 2 3 4 5 6
Einstellregler:
1. Time control
for water arrest, default set-
ting 1 min (setting range 30 s
to 10 min).
3. DIP switches:
Function activation – DIP switch 1–6:
DIP switch
Function
1
Flushing mode
2
Cleaning stop
3
Continuous flow
4
Stagnation rinse
5
Stagnation rinse time
6
Shut-off delay (ON = 5 s, OFF = 3 s)
SKY
1
Time control
2
Sensitivity control
3
DIP switches
2. Sensitivity control
regulates the shut-off sensiti-
vity of the fitting (1 = sensitiv,
20 = insensitiv)
Move counterclockwise to decrease the setting.
Move clockwise to increase the setting.
Factory setting
ON
OFF
OFF
OFF
OFF
OFF
Washbasin fitting
Position of the
touch sensor
Rule applies to all controls:
Description
Page 19
Page 19
Page 20
Page 21
Page 21
Page 22
SanTec SKY
EN
!
15

Werbung

Inhaltsverzeichnis
loading