Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - Battery Replacement - WimTec ECOSAN W6 Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ECOSAN W6:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
ECOSAN W6

Maintenance - battery replacement

1
4
1
2
!
Note:
At low battery level, the moni-
toring LED flashes once every
4 s - triggering is not possible!
The fitting will only resume
normal operation once the
battery has been replaced!
40
Washbasin fitting
2
2
1
5
1.
Loosen locking screw on the underside of the sensor hood
using the Allen key (size 2) provided (3 rotations)�
2.
Rotate hood anticlockwise and remove to the side�
3.
Remove the electronics module from the sensor hood and
insert new battery�
4.
Insert the electronics module into the sensor hood� Position
sensor hood (sensor window gently tilted upwards) and
rotate clockwise until the stop�
5.
Then tighten the locking screw by hand�
6.
After the solenoid valve detection, an automatic range-
span adjustment is performed� The user must not be in the
operating range of the valve� After the control LED flashes
3 times, the valve is ready for operation�
WimTec ECOSAN W6
3
6
Use the correct +/- polarity!
3 x