Description of the functions
Thermal desinfection:
!
Note:
In order to guarantee the
correct thermal disinfection,
the continuous fl ow function
must be activated (see page
35) and fl ushing stop time set
to 10 min (see page 27)�
3
2
38
Washbasin fi tting
1
4
1
1.
Press the hot water restricting button and rotate anticlock-
wise until the stop�
2� Use the Allen key (size 1�5) to loosen the Allen screw
(3 rotations)�
3.
Press the hot water restricting button again and rotate
anticlockwise until the stop�
4.
Trigger continuous fl ow (see page 35)�
5.
Once thermal disinfection has been performed, turn the
thermostat handle back clockwise and gently tighten the
Allen screw�