Herunterladen Inhalt Inhalt Diese Seite drucken

Configuring The Functions; Setting Controls; Dip Switches - WimTec SMART HYPlus Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SMART HYPlus:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
SMART

Configuring the functions

Setting controls

6
3
12
0,5
24
h
1. Interval control
for the interval of the sta-
gnation flush, default 12 h
(setting range 0,5 h - 24 h).

DIP switches:

Function activation – DIP switch 1–6:
DIP switch
Function
1
Active range (ON = 15 cm, OFF = 12 cm)
2
Cleaning stop
3
Continuous flow
4
Intelligent stagnation flush
5
Flushing stop (ON = 10 min, OFF = 1 min)
6
Shut-off delay (ON = 3 s, OFF = 1 s)
20
Washbasin fitting
HyPlus
60
30
10
s
2. Minimum flushing
duration control
for the duration of the
stagnation flush, default 30 s
(setting range 10 s - 180 s).
WimTec SMART
HyPlus
Rule applies to all controls:
120
Move counterclockwise to
180
Factory setting
decrease the setting.
Move clockwise to
increase the setting.
Description
ON
Page 22
OFF
Page 23
OFF
Page 24
ON
Page 25
OFF
Page 26
OFF
Page 26
!

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis