Herunterladen Inhalt Inhalt Diese Seite drucken

Construction And Function; Construction; Function; Led Display - Balluff BTL6-U110-M0500-PF-S4 Betriebsanleitung

Micropulse wegaufnehmer im profilgehäuse flach btl6-u110-m_ _ _ _-pf-s4 serie
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL6-U110-M _ _ _ _ -PF-S4
Micropulse Transducer in a Flat Profile Housing
3

Construction and function

Output signal rising:
Error signal
100 %
0 %
Null point
1)
13
73
~80
Mounting clamps with insulating bushes
and ISO 4762 M5x25 cylinder-head screws,
max. tightening torque 2 Nm
Fig. 3-1:
BTL6... transducer, construction
3.1

Construction

Electrical connection: The electrical connection is made
via a connector (see Type code breakdown on page 20).
BTL housing: Aluminum housing containing the
waveguide and processing electronics.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on page 17).
Nominal length: To optimally adapt the transducer to the
application, the following nominal lengths are available:
Nominal length
50 to 4572 mm
3.2

Function

The BTL6 transducer contains the waveguide which is
protected by an aluminum housing. A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
www.balluff.com
End point
Nominal length =
Measuring range
2)
~250
~250
Grading
5 mm
1) Unusable area
2) Not included in scope
1)
73
~80
15
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic speed.
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is
converted by a coil into an electrical signal. The travel time
of the wave is used to calculate the position. The
measuring value is output as a 32-bit value with a sign
relative to the null point.
3.3

LED display

In normal operation the LED indicates the
operating states of the transducer.
LED
Operating state
Green
Normal function without IO-Link
communication
Magnet is within the limits.
Normal function with IO-Link communication
Green
flashing
Magnet is within the limits.
inversely
Red
Error
No magnet or magnet outside the limits.
Tab. 3-1:
LED display
of delivery
2)
BTL5-P-3800-2 magnet
34.8
50
LED
68
english
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis