1 Introduction

The Curapuls 670 is a microprocessor-controlled unit for pulsed shortwave therapy, applied by means of
one or two inductive electrodes. The equipment is only meant to be used by competent personnel in
physiotherapy, rehabilitation or adjacent areas.
1.1

Simple and safe operation

The various parameters are selected by means of push-button controls, and are set using one central
control. The microprocessor controls and monitors all functions during operation. Directly after switching
on, the microprocessor automatically tests the electronics of the Curapuls 670 for safety and correct
functioning.
1.2

Optimum energy transfer

Considerable attention has been paid to the way in which the high-frequency energy is transferred to the
tissue. Continuous microprocessor-controlled fine tuning ensures optimum adaptation to the tissue
characteristics.
Special high-output inductive electrodes have been developed for use with the Curapuls 670. These are
of the "Circuplode" type, and are available in various diameters and shapes. They are provided with
screening for the electrical field so that only a magnetic field is created. The type of electrode
(large/small/ellipse-shaped) connected to each channel is recognized automatically, eliminating the
chance of incorrect settings.
If the load on the electrode is insufficient, no power will be supplied. This is indicated by a warning lamp
on the electrode and by the sounding of a buzzer. This form of power transfer indication prevents
inefficient treatment, thus contributing to optimum treatment results.

2 Product liability

A law on Product Liability has become effective in many countries. This Product Liability law implies,
amongst other things, that once a period of 10 years has elapsed after a product has been brought into
circulation, the manufacturer can no longer be held responsible for possible shortcomings of the product.
To the maximum extent permitted by applicable law, in no event will Enraf-Nonius or its suppliers or
resellers be liable for any indirect, special, incidental or consequential damages arising from the use of or
inability to use the product, including, without limitation, damages for loss of goodwill, work and
productivity, computer failure or malfunction, or any and all other commercial damages or losses, even if
advised of the possibility thereof, and regardless of the legal or equitable theory (contract, tort or
otherwise) upon which the claim is based. In any case, Enraf-Nonius's entire liability under any provision
of this agreement shall not exceed in the aggregate the sum of the fees paid for this product and fees for
support of the product received by Enraf-Nonius under a separate support agreement (if any), with the
exception of death or personal injury caused by the negligence of Enraf-Nonius to the extent applicable
law prohibits the limitation of damages in such cases.
The opposing party (product's user or its representative) shall disclaim Enraf-Nonius from all claims
arising from third parties, whatever nature or whatever relationship to the opposing party.

3 User's responsibilities

3.1

General

The Curapuls 670 is a modern, safe and easy-to-handle apparatus, which has been developed,
produced, calibrated and packed with the greatest care.
To operate the Curapuls in the correct and proper manner, it is important that you read this operating
manual before use. Also, make sure this manual is available to all personnel at all times. For use of this