Herunterladen Inhalt Inhalt Diese Seite drucken

Installation In An Exposed Wastewater Pipe - Kessel Pumpfix F Comfort Anleitung Für Einbau, Bedienung Und Wartung

Rückstaupumpanlage für fäkalienhaltiges und fäkalienfreies abwasser
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
3.4 Installation in an exposed wastewa-
ter pipe
Fig. 7
The version for free-standing set-up is delivered
with a protective hood to prevent damage to
the components following commissioning. Fig.
7 shows the cable ducts.
Installation in groundwater
3.5
(Seal set art. no. 83023
If the valve is to be installed in groundwater,
the flange serves as the necessary sealing
level for a white or black tub (see Figure).
For this purpose, seal sheeting is clamped
between the plastic counterflange and the
compression seal flange integrated on the
drain body, and screwed together using the
enclosed screws.
The sheeting used on site can be used as
seal sheeting. For installation in a waterpro-
of white tub, KESSEL also has matching
seal sheeting available made of natural rub-
ber NK/SBR, where the bore holes for the
screws have already been cut out (see Fig. 8).
If it is necessary to perforate the waterproof
concrete tub to connect feed pipes, cable
conduits etc., these holes must also be set
up waterproof. Maximum groundwater resi-
stance is 2 m.
Installation example "black tub"
BWS
*
4
KESSEL-Pumpfix F, Staufix FKA, Staufix SWA, Controlfix
Compression seal flange with seal set art. no. 83023
Extension art. no. 83071
Adapter DN 100 with compression seal flange made of stainless
steel art. no. 27198
3. Installation
Installation with extension (order no.
83071).
Use of the extension allows the flange
height to be individually adjusted. The
attachment must be shortened to the re-
quired height if necessary.
3.6
Special features of Pumpfix F
Comfort
Pumpfix F Comfort has an integrated drai-
ning function for surface water drainage.
3.7
Set-up
Connection of the draining function to the
feed cover is via the enclosed draining
connection. Insert the draining connection
into the prescribed opening and lock using
the one-handed quick-action closure.
Depending on installation depth (installati-
on depth of the upper cover section), the
draining connection must be shortened to
the respective length (see Fig. 9) or exten-
ded using HT-pipe DN 70 if recessed in-
stallation using extension (art. no. 83071)
is used.
Tiles
Fliesen
Screed
Estrich
Insulation
Dämmung
Concrete floor
Betonboden
Protective concrete
Schutzbeton
Sealing
Abdichtung
Underfloor
Unterbeton
2
3
1
Fig 9
Installation example "white tub"
BWS *
4
5
Elastomer sealing sheet art. no. 27159
Upper cover section with plastic cover plate
Control unit
Locking lever
17
Fig. 8
Pumpfix F Comfort
Tiles
Fliesen
Screed
Estrich
Insulation
Dämmung
Concrete floor
Betonboden
2
1
Seal seat
Dichtun
(83023)
- Gegen
• Counterflange
• Sealing sheet
- Dichtu
Pressdichtungs-
flansch
WU-Beton