Problem solving
Problem
The device is plugged in,
no diodes are on.
Heating element is not
heating, outside diodes are
blinking alternately.
The device is heating de-
spite turning it off with the
button.
If the problem continues please contact Your local Distributor.
EN
Possible cause
Problem with the
connection.
Temperature sensor has
been damaged.
Overheating of device.
Damaged electronics.
Solution
Check the connection of
the power wire, the plug
and the socket.
Disconnect the device
completely, wait until the
radiator cools down and
re-connect it again.
Check and confirm that the
heating element's out put
does not exceed the rec-
ommended output of your
radiator. Check and reduce
the water tem perature in
the central heating system-
must not exceed 82°. In
electric-only version check,
if the radiator is proper-
ly filled with the heating
agent.
Disconnect the device
completely, wait until the
radiator cools down and
re-connect it.
21