Device malfunction alert
DRY Heater has built-in malfunction moni-
toring and alert functions.
Device malfunction is signalled in the fol-
lowing way: the two outer diodes shine with
constant light while the middle diode flash-
es in the following manner — several flash-
es followed by a longer break. The number
of diode flashes indicates an error code as
described below:
a) "Running in dry conditions" (error code:
2 flashes) — electronic system identi- fied
a situation indicating too little heating
liquid inside the towel rail. Check to see
if the towel rail has been properly filled
with heating medium.
b) "Overheating" (error code: 3 flashes) —
the temperature of heating liquid inside
the towel rail is too high
• If the heater heats up despite being
turned off, it is likely that the electron-
ics have been damaged. The heater
should be returned to the supplier/
manufacturer for repair.
• If the heater is installed inside a tow-
el rail that is connected to a central
heating system with hot water in the
system, an alert does not mean that
the heater has been damaged. The
alert signals that temperature of the
EN
installation is too high. Please ensure
that temperature of the water inside
the installation does not exceed 82° C
as this could cause damage to the
heater's thermal fuse.
c) "Temperature sensor damaged" (error
code: 4 flashes) — There is a possibili-
ty of electronic system malfunction. The
heater will most likely need repair.
d) "Warning against possible heat escape
into the system in central heating instal-
lations" (error code: 5 flashes) — there
is a risk of a heat escape into the sys-
tem if device is operating with the cen-
tral heating system on and system wa-
ter in circulation.
Attention: when closing the central heating
installation valves, ensure that 1 valve re-
mains open. This will prevent pressure in
the towel rail from rising excessively.
The malfunction alert may be removed by
turning the heater off and on again.
In the case of a malfunction alert, turn the
heater off and wait for the towel rail to cool
down. Check the device for a possible cause
(referring to the manufacturer "problem solv-
ing" guide) and try to resolve it. If the heater
is still signalling malfunction after it is turned
on again, you should contact your supplier
or, alternatively, the product manufacturer.