Intended use of device
The heating element is an electric device
intended solely for installation in radiators
(standalone or connected to the central heat-
ing system).

Technical information

Type of electrical connection:
Heat outputs available:
Towel rail connection thread:
Casing protection class [IP]:
Length of heating element:
* Device intended to be connected permanently to the system
10
User manual MEG, DRY, MOA, REG 2, REG 3
Model markings
(power cable type):
Power supply:
Insulation class:
Heating element power output should be
matched with radiator output for parame-
ters of 75/65/20° C
PB (Straight cable without plug) *
PW (Straight cable with plug)
SW (Spiral cable with plug)
Y: MEG, MOA, MOA IR, REG 3, DRY
Z: REG 2
120, 200, 300, 400, 600, 800, 1000, 1200 [W]
230 V / 50 Hz
Class I
G 1/2"
IPx4: MEG
IPx5: REG 2, REG 3, MOA, MOA IR, DRY
120 200 300 400 600 800 1000 1200 [W]
315 275 300 335 365 475 565 660 [mm]