Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Environmental Conditions - Jackle conMIG 445 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

22. Technical data

Power source
Supply voltage, 50 Hz
Current consumption
Fuse
Max. power draw
Set point range
Operating voltage
Open-circuit voltage
Duty cycle 60 % (40°C)
Duty cycle 100 % (40°C)
System of protection
Insulating category
System of cooling
Weight (solo)
Dimens. L x B x H (mm)
Noise emission
Wire feed
Wire feed motor
Wire feed speed
Diameter of wire
Weight (solo)
Dimens. L x B x H (mm)
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 22kVA (unit) + 30% = 30kVA. The generator for this unit must have 30kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.

23. Environmental conditions

The power source must be operated at a temperature between -10°C to +40°C and a relative humidity of 50% at
40°C or up to 90% at +20°C. The ambient air must be free of unusual amounts of dust, acids, corrosive gases
or substances, etc., unless they occur during welding.
To prevent damage to the machine the temperature around the machine is controlled.
If this temperature is below -10°C or above + 40°C, the following text appear on the display and the machine
can not be started:
Only when the temperature is in the prescribed range, the welding operation can be started.
Operating manual
conMIG 400
400 V, 3 Phase, +/- 10%
Imax = 32 A, Ieff = 25A
32 A slow
22 kVA
50 - 400 A
16,5 – 34 V
20 – 52 V
400 A / 34 V
350 A / 31,5 V
IP 23
H (180° C)
F
186 kg
1070 x 490 x 945
< 70 dB(A)
DVK 3
42 V, 100 W
0,8 - 24 m/min
0,8 - 1,6 mm
20 kg
580 x 270 x 560
t°C - int – ‚measured temperature value'
conMIG 445
400 V, 3 Phase, +/- 10%
Imax = 35 A, Ieff = 27A
32 A slow
24,5 kVA
50 - 450 A
16,5 – 36,5 V
20 – 57 V
450 A / 36,5 V
400 A / 34 V
IP 23
H (180° C)
F
238 kg
1100 x 500 x 1000
< 70 dB(A)
DVK 4
42 V, 140 W
0,8 - 24 m/min
0,8 - 1,6 mm
28 kg
650 x 450 x 360
conMIG 400/445/545
conMIG 545
400 V, 3 Phase, +/- 10%
Imax = 52 A, Ieff = 40A
50 A slow
36,5 kVA
50 - 550 A
16,5 – 41,5 V
20 – 66 V
550 A / 41,5 V
450 A / 36,5 V
IP 23
H (180° C)
F
230 kg
1100 x 500 x 1000
< 70 dB(A)