Herunterladen Inhalt Inhalt Diese Seite drucken

Jackle conMIG 445 Betriebsanleitung Seite 43

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The values can be changed by rotating the left knob.
If the value is not changed for more then 2 seconds, the value will be stored.
During welding:
Operation mode MIG:
During the welding operation, the choc function is accessed and can be modified by tapping the button Fx.
The left display shows Choc, in the middle display is the current value.
Now, with the left knob, the value can be changed.
By another tap on the Fx button, the wire speed correction is shown in the middle display and the LED % is
light. Now, with the left knob, the value can be changed (between -50% and +50%).
Function ► MC 4-5
In stand-by mode (not during welding):
By tipping short on the control key ► the following functions can be changed for
curve
(only in stand-by mode):
Operation Mode MIG:
- choke (Display Choc – only MC4):
- start - speed (StS):
- wire burn back (bUb):
The values can be changed by tipping on the keys ▲ or▼.
If the value is not changed for more then 2 seconds, the value will be stored.
During welding:
Operation mode MIG:
During the welding operation, the choc function is accessed and can be modified by tapping the button ►.
The left display shows Choc, in the middle display is the current value.
Now, with the middle knob, the value can be changed.
By another tap on the ► button, the wire speed correction is shown in the middle display and the LED % is
light. Now, with the middle knob, the value can be changed between -50% and + 50%.
To block the control unit - CODE (MC 3)
To block the control unit:
Tip on key Fx as long as 'CodE' appears in the display. Now rotate the left rotating knob to a number
between 0000 and 9999.
If the right number is in the display press the key 'wire-feed-in'. Now the control unit is blocked. Only the
functions gas test, wire-feed-in and wire-speed correction are available. All other functions are blocked.
To unlock the control box, tip again on the Fx key, until 'CodE' appears.
Now rotate to the same number, as for blocking. After tipping on the key 'wire-feed-in' the control unit is
unlocked.
Option Fx (MC 3)
To adjust the low-level basic settings, press the control key 'Fx' for more then 1 second. The following
options can be changed:
- EC 1/2: Specify the functions of the remote control potentiometer (see next page)
- Hold: adjust the time for the display hold (0 = endless, -> 25s)
- Reset the jobs or factory settings (see next chapter)
- Torch type and length set: tap until ‚tch' appears in the left display,
in the middle display the following 3-digit numeral appears:
1st digit: 1 = gas cooled torch, 2 = water cooled torch
2nd + 3rd digit: length of the torch (2, 3 or 4m)
adjust with the rotating knob exactly the mounted torch
e.g.: 204 = water cooled torch with 4m length
- Remaining cable length set (earth cable and perhaps torch hose package)
tap until ‚cbl' appears in the left display, now adjust the complete cable length
(without torch cable length!) in the right display.
Operating manual
step less correction of the welding choke
from ‚- 80 harder' to ‚+ 80 smoother' then normal '0'
10 to 100% of the welding speed
-60ms (long, pointed) to +90ms (short, ball wire end)
conMIG 400/445/545
each welding
Page 40

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Conmig 400Conmig 545

Inhaltsverzeichnis