Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

29. Control unit MC 5

1
2
3
4
1 – Display for wire speed (m/min) or wire speed correction from -50% to +50% flashing dot: HOLD Function
active
2 – LED display if 2-cycle, 4-cycle or 2-cycle - spot is active
3 – Control key to change between 2-cycle, 4-cycle or 2-cycle – spot by tipping on the key
4 – Turning knob to change the wire feed speed
5 – Display for the value of the start speed, burn-back-time, the welding voltage or the welding current
6 – LED display if the choke, start speed, burn-back-time, the welding voltage or the welding current is active
7 – Control key to change between the choke, start speed, the burn-back-time, the welding voltage or the
welding current (or if spot is activated the spot time)
8 – Control key to activate the gas test function, or to increase the value of the choke, wire-creep-in speed,
burn-back-time or the material thickness, when the LED (6) is flashing
9 – Control key to activate the wire-feed-in function, or to decrease the value of the choke wire-creep-in speed,
burn-back-time or the material thickness, when the LED (6) is flashing
Operating manual
4-cycle
2-cycle
burn back
start
V
speed
welding voltage
MC 5
spot
welding
A
current
conMIG 400/445/545
5
6
V A
7
8
TEST
9
Page 37

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Conmig 400Conmig 545

Inhaltsverzeichnis