19. Technical data

Power source
Supply voltage, 50/60 Hz
Drawing of current
Fuse
Max. power draw
Set-point range
Operating voltage
Open-circuit voltage
Voltage steps
Duty cycle 30 % (40° C)
Duty cycle 60 % (40° C)
Duty cycle 100 % (40° C)
System of protection
Insulation category
System of cooling
Weight
Dimensions L x W x H (mm)
Noise emission
Wire feed
Wire feed motor with
Wire feed speed
Diameter of wire
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 13kVA (unit) + 30% = 17kVA. The generator for this unit must have 17kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.

20. Environmental conditions

The power source must be operated at a temperature between -10° C to +40° C and a relative humidity of 50% at
40° C or up to 90% at +20° C. The ambient air must be free of unusual amounts of dust, acids, corrosive gases or
substances, etc., unless they occur during welding.
To prevent damage to the machine the temperature around the machine is controlled.
If this temperature is below -10° C or above + 40° C, the following text appear on the display and the machine can
not be started:
Only when the temperature is in the prescribed range, the welding operation can be started.
Operating manual
conMIG 300
400 V, 3-phase, +/- 10%
Imax = 19 A, Ieff = 11A
16 A slow
13 kVA
40 - 300 A
16 - 29 V
20 - 45 V
12
300 A / 29 V
230 A / 25.5 V
200 A / 24 V
IP 23
H (180° C)
F
78 kg
900 x 490 x 740
< 70 dB(A)
42 V, 50 W
1,0 - 24 m/min
0.8 - 1.2 mm
t° C - int – ‚measured temperature value'