Electrical connections

7
Electrical connections
The complete circuit diagram for the alarm system can be found in Fig. 8, page 7.
No. in
Fig. 8, page 7
1
2
3
4
5
6
7
8
9
10
11
All plugs are coded so that you cannot connect them incorrectly.
7.1

Laying cables

When laying electric connections, ensure that
They are not kinked or twisted
They do not rub on edges
They are not laid in sharp edged ducts without protection (see Fig. 2, page 3).
Caution!
Before making any drill holes, ensure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing (see
Fig. 1, page 3).
When laying cables in the engine compartment or boot, use existing openings
with rubber seals wherever possible.
Where there is no suitable opening, drill a hole with a diameter of approximately
13 mm, and insert a cable duct sleeve.
Note
Pull the socket connector of the cables through the cable sleeve, before
inserting the sleeve in the bodywork.
Lay out the cables in the motor or boot so that they cannot be damaged under
any circumstance (e. g. by flying grit).
Insulate all unused cable ends.
56
Description
Control unit
Shock sensor
Status LED
Drive-off block (optional)
Convenience output
Bonnet contact switch
Boot contact switch
Door contact switch
Indicator switch
Indicator
Alarm siren
MAGIC SAFE