MAGIC SAFE
7.2
Connecting the P1 main cable tree (see Fig. 6, page 6)
Plug the P1 cable tree into the corresponding connection on the control unit.
Green/brown (P1.7)
If the indicators are positively charged (the cables to the indicators conduct +12 V,
when the indicators are activated):
Connect this cable to +12 V.
If the indicators are negatively charged (the cables to the indicators conduct an
earthed charge, when the indicators are activated):
Connect this cable to earth.
Undo the soldered connections for the two diodes (fig. 8.12, page 7) in the black/
white and black/green cables and reverse their position (polarity) and resolder
them.
Black/white and black/green (P1.8)
Connect the black/white cable to the right indicator cable.
Connect the black/green cable to the left indicator cable.
Red (P1.9)
Connect this cable to a cable with a permanent +12 V charge (terminal +30).
Black (P1.10)
Connect this cable to earth (terminal -31).
Brown (P1.11)
Guide this cable through the splash-protection wall in the engine compartment.
Connect this cable to the red alarm siren cable.
Connect the negative pole of the alarm siren to earth.
Connecting the central locking
MAGIC SAFE has a universal connection for central locking to enable standard cen-
tral locking and engine-powered retrofitted central locking to be connected to the sys-
tem.
You can find the cable colours and their functions in the following table:
Colour
Blue/yellow
Blue/red
Red/black
Grey/yellow
Grey/red
Red/yellow
Plug
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
Function
Open normally closed
Open together
Open normally open
Closed normally closed
Close together
Close normally open