7.3
Connecting the P2 cable tree
Plug the P2 cable tree into the corresponding connection on the control unit.
Yellow (P2.2) and green (P2.3)
The connection of the yellow and green cable depends on the switching principle of
the door contacts which are installed in the vehicle (interior lighting switch).
If the vehicle has a negatively connected interior lighting (the cable from the door
switch is earthed when the door is opened), connect the green cable to the cir-
cuit cable of the interior lighting switch.
If the vehicle has a positively connected interior lighting (the cable from the door
switch is carries +12 V), connect the yellow cable to the circuit cable of the inte-
rior lighting switch.
Caution!
With vehicles with interior lighting delays fitted as standard, program posi-
tion 8 must be set to "ON" ("Software functions" chapter on page 76). This
prevents you receiving three confirmation signals when the system is acti-
vated.
Orange (P2.4)
Connect this cable to a connection which is switched by the ignition
(terminal 15).
Blue/black (P2.5)
The blue/black cable serves as an output for the convenience functions. The conven-
ience output is earthed and can be charged with up to 350 mA. The table in the
"Using convenience functions" chapter on page 77 shows you which convenience
functions you can use.
Connect this cable according to your requirements.
Grey (P2.6)
Guide this cable through the splash-protection wall to the bonnet contact switch.
Connect this cable to a cable which is earthed when the bonnet is opened.
If you cannot find such a cable, install the bonnet contact switch included in the
scope of delivery.
If you wish to use the grey cable not only to monitor the bonnet contact switch but
also the boot switch, proceed as follows:
Connect two inverse diodes (see Fig. 9, page 8) to prevent interference between
the bonnet contact switch and the boot lighting.
No. in
Fig. 9, page 8
1
2
3
4
Description
Boot light
Boot contact switch
Inverse diode
Bonnet contact switch