Electrical connections
Connecting to the central locking
Determine the switching function of the original central locking.
You require a circuit diagram of the central locking for this which you can obtain
from your vehicle dealership.
If no original circuit diagrams are available, you will need to determine the func-
tion of the control cables which run from the control device of the central locking
to the vehicle doors.
Caution!
Only connect MAGIC SAFE via the control cables of the central locking
and not using other cables.
Connecting to other cables than the control cables or using an incorrect cir-
cuit plan can lead to defects in the central locking and the remote control.
Determine the control time of the central locking.
In some vehicles for example Mercedes, it may be the case that a control time
of 0.5 s is not sufficient to completely activate the central locking. In such cases
you need to set the control time with software function 4 (see "Software func-
tions" chapter on page 76) to 4 s.
Connect MAGIC SAFE in accordance with the appropriate circuit diagram:
Vehicles without a servo motor in the driver's door (driver's door cannot be
locked and unlocked from the passenger's door) or with pressure vacuum cen-
tral locking without electrical control cables: see Fig. 10, page 8
In these cases you require an additional servo motor, WAECO type no. ML-11
for the driver's door.
Two cables from negative to +12 V: Fig. 11, page 9
Two +12 V pulse control cables: Fig. 12, page 9
Two negative pulse control cables: Fig. 13, page 10
One open and negative pulse control cable: Fig. 14, page 10
One +12 V and negative pulse control cable: Fig. 15, page 11
For the connection to the WAECO central locking ML-44(22) IR: Fig. 16,
page 11
Connection to the WAECO central locking ML-44(22): Fig. 17, page 12
Insulate any unconnected cables.
No. in
fig. 11 to fig. 15
1
58
Description
Control device of the vehicle's own central locking
MAGIC SAFE