Herunterladen Inhalt Inhalt Diese Seite drucken

Disassembly And Disposal - Flotec EVO-MULTIMAX 340 KIT Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
•   For self-priming pumps only: The li-
quid column above the check valve on
the delivery pipeline prevents self-pri-
ming of the pump = drain the delivery
pipeline. Check that check valve does
not retain liquid in the delivery pipe-
line. Repeat the start-up procedure.
Pump performance is reduced
•   Pipelines obstructed = check pipelines
•   Pump is not primed correctly = repeat
the "pump priming" procedure
•   For self-priming pumps only: the in-
ternal valve has not closed = gradually
close a valve until there is a visible in-
crease in pressure or flow. Then open
the valve gradually until the required
flow rate is reached.
Pump performance is unstable
•   Pump suction pressure too low or
cavitation = check the pump inlet
conditions
•   Suction pipe is partially obstructed
with impurities = clean the suction
pipe
•   Leak from suction pipe = repair or
replace suction pipe
•   air in suction pipe = bleed the suc-
tion pipe, repeat the "pump priming"
instructions
•   +For self-priming pumps only: The
differential pressure inside the pump
is too low = gradually close a valve
until delivery pressure stabilizes and
the noise level is reduced
The pump rotates in the opposite direc-
tion when shut down
•   Foot valve or check valve defective or
blocked in the open position = remove
and clean or replace the valves
•   Leak from suction pipe = remove and
repair suction pipe
DISASSEMBLY AND
DISPOSAL
Before any intervention on the
pump, disconnect the electrical
mains. Ensure that the electrical
power supply cannot be restored inadver-
tently.
•   Disconnect the pump electrically from
the system according to safety stan-
dards
•   Open the tap nearest to the pump to
decrease the system's pressure
•   Before disassembly, close the shut-
off valves on the delivery side, and if
present also close the shutoff valve on
the suction side.
Note the position of the filler
hole, which is also used as a
bleed point. Ensure that the liq-
uid on outlet cannot cause damage or
physical injury.
•   Loosen the filler cap to reduce the
pressure of the liquid remaining be-
tween the two valves
•   Remove the drain cap from the pump
body to completely empty the pump
This product or any part of the latter must
be disposed of in accordance with lo-
cal standards using the public or private
waste collection authorities as required.
ENGLISH